This control box has the smallest footprint and the lowest price of the Y range with waterproof enclosure. It has a modern and aesthetic design, and the same professional concept than other products of this range.
Because of their small size (120 x 70 x 40 mm), these controls can be wall mounted with 2 screws 55 mm distance, hand held or just simply laid on the working table.
Enclosure: PC-ABS, black color,small footprint , can be hand held of wall mounted
Ingress protection rating: IP54 (IEC 60529)
Mechanical impact resistance: IK05 (EN 62262) Digital display not included.
Flammability: UL94-V0
Electrical connection: on a closed screw terminal connection block cavity located backside, for wire gauges up to 2.5 mm². Cables are secured by a saddle retainer, and grommets. Ground, neutral and phase can be connected in input and output.
Power inlet and outlet: through grommets for cables dia. 6 to 8 mm. Over-molded cables on request (MOQ apply)
Adjustment: by up, down and set keys
Display: selectable in °C or °F (4 digits)
Power supply: 90-250VAC, 50 or 60Hz
Temperature control action: ON-OFF or PID with auto-tune function
Differential: adjustable when on-Off action is selected
Mounting: Wall mounting, for screws dia. 4 to 6 mm, 55 mm distance
Identification: Location backside for 20 x 40 mm identification label, adhesive or riveted
Electrical contact: Relay output, 10A 250V AC res (15 A120V AC). Open on rise or close on rise action can be selected
Temperature sensor: This control can be supplied with or without sensor. The cable can be protected by a plastic flexible corrugated tube.
This controller is multi sensor type, user settable with the following input choice:
Parameters |
Sensor |
Temperature range (°C) |
t |
Type T Thermocouple |
-200~400 |
J |
Type J Thermocouple |
-200~700 |
E |
Type E Thermocouple |
-200~900 |
K |
Type K Thermocouple |
-200~1300 |
r |
Type R Thermocouple |
-50~1600 |
S |
Type S Thermocouple |
-50~1600 |
b |
Type B Thermocouple |
350~1800 |
W |
Type WRE Thermocouple |
0~2300 |
Cu50 |
Cu50 |
-50.0~150.0 |
Pt100 |
P100 |
-199~600 |
Pt10.0 |
P10 |
-199.9~600.0 |
|
|
Wiring diagram
Main references without cords*
Main features |
Reference |
Without temperature sensor |
Y5F090A0000NUDF2 |
With PT100 RTD, 5 x 30 mm SS probe, 2 m protected cable |
Y5FR9BA0000NUDF2 |
With PT100 RTD, 5 x 30 mm SS probe, 2 m un- protected cable |
Y5FR9CA0000NUDF2 |
With K thermocouple, 5 x 30 mm SS probe, 2 m protected cable |
Y5FK9BA0000NUDF2 |
With K thermocouple, 5 x 30 mm SS probe, 2 m un-protected cable |
Y5FK9CA0000NUDF2 |
|
* Reference with Male Euro 1m H05-VVF-3G1 cord+ no connector euro1m H05-VVF-3G1 cord: replace 0000 by EJHJ
Reference with 2 euro cords 1m H05-VVF-3G1 without connector or plug: replace 0000 by HJHJ
Reference with UL SJT 3 x AWG16, 1m Male cord + SJT 3 x AWG16, 1m Female cords: replace 0000 by UJVJ
Reference with Male UL SJT 3 x AWG16, 1m cord + no connector UL SJT 3 x AWG16, 1m cord: replace 0000 by UJSJ
Reference with 2 UL SJT 3 x AWG16 1m cords without connector or plug: replace 0000 by SJSJ |
|