Size and pressure |
Flow sensing: Cleavable paddle |
Mounting: ¾” BSPP brass union nut |
Contact: Reed switch, close on
flow rise |
Electrical rating |
Mounting position |
Type |
PN25 |
 |
 |
 |
 |
 |
R1V |
DN≥15 |
Main uses: General application in flow detection. Recommended mounting position is on horizontal pipes, but can be mounted in any position. For liquids flow detection on dia. 15 to 100 mm pipes. Body and union nut in brass for improved mechanical strength and pressure resistance. Connection box with terminal block or connectors, and detection point adjustment screw
Functional principle: Balanced magnetic paddle mounted perpendicular to the flow and activating a reed switch through the wall. The return of the paddle is by made by magnetic action, without spring. No seal or liquid can pass between the piping system and the electrical contact.
Usable for industrial applications in non-corrosive liquids. Must not to be used for liquids containing magnetic particles or high viscosity liquids, which block the movement of the pallet.
Adjustment: - By cleaving the paddle - Fine adjustment by screw driver on internal dial
Paddle shaft: Titanium, providing an outstanding corrosion resistance, and improved mechanical live
Main housing material: Brass
Paddle: Polypropylene, 15 mm width, with 4 sections, numbered 1 to 4, can be cleaved for adjustment to pipe size
Pipe mounting: Nickel plated brass union nut,¾ BSPP, mounting on ¾ BSPP male thread with gasket. Recommended torque: 10±1 Nm
Gasket: NBR
Electrical rating: Max 1A, Max 70W, Max 250V, resistive load. Use on inductive circuits reduces electrical rating. We recommend to protect the reed switch with contact protection device when used in inductive loads
Electric contact type: Normally open, closes by flow rise
Liquids compatibility: For use with clean water and liquids without magnetic particles and without chemical incompatibility with brass, PPO and titanium
Nominal pressure at 20°C: 2,5 MPa (PN25)
Liquids temperature range: 5 to 100°C (Do not withstand water freezing inside pipe)
Ambient temperature range: 5 to 80°C
Ingress protection: IP65
Calibration tolerances: +/-15% (on paddle operating force at end of paddle 1)
Electrical connection:
Standard: IP64 connection box, with screw terminal connection block, M16x1.5 ISO cable gland
Options:
- Connection box with EN17530-803-A (DIN43650-A) connector
- Connection box with IEC947-5-2 M12x1 4 pins connector
Installation instructions:
- Check carefully the paddle orientation: The arrow on housing must be exactly parallel to the pipe
- A 5 mm minimum gap must be respected between end of the paddle and tube wall opposite to the fitting.
- We recommend the use of nozzles of length less than or equal to 18mm between the gasket seat and the inside of the tube and with an inner diameter greater than or equal to 13.5 mm, to avoid blocking of the paddle.
Accessories: 3/4” male PVC saddles for DN40 to DN100 (OD) PVC pipes, and other fittings: see last section of this catalogue
Important notice: In the case of plastic pipes (PVC, PE), the DN (nominal diameter) corresponds to the outside diameter and wall thickness is variable depending on the application. This must be taken into account to avoid blocking the paddle. In the case of metal pipes, the inner diameter corresponds to the DN. Flow values data are for tubes whose internal diameter corresponds to DN. |
|

Cable connection model
1: Paddle
2: ¾” BSPP Brass union nut and brass body
3: Connection box |
4: Adjustment screw
5: EN17530-803-A (DIN43650-A) connector (Option)
6: IEC947-5-2, M12x1,4 terminals connector (Option) |
Pipe mounting configurations
|
|
Average flow detection values (Liters/min)
Paddle
length |
Pipe ID (mm) |
15 |
20 |
25 |
32 |
40 |
50 |
63 |
100 |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
*Close |
**Open |
1-m |
2,7 |
2,3 |
4,8 |
4,5 |
13 |
11 |
22 |
20 |
38 |
35 |
67 |
47 |
167 |
112 |
472 |
317 |
1-H |
4,3 |
3,3 |
7,3 |
6,5 |
18 |
17 |
29 |
27 |
53 |
48 |
83 |
72 |
218 |
142 |
616 |
401 |
1-M |
5,5 |
3,2 |
14 |
12 |
25 |
22 |
38 |
35 |
67 |
60 |
132 |
108 |
262 |
202 |
740 |
571 |
1+2-m |
|
|
|
|
|
|
|
|
20 |
18 |
37 |
32 |
68 |
52 |
192 |
155 |
1+2-H |
|
|
|
|
|
|
|
|
30 |
28 |
53 |
43 |
88 |
72 |
248 |
203 |
1+2-M |
|
|
|
|
|
|
|
|
40 |
37 |
67 |
63 |
123 |
115 |
347 |
324 |
1~3-m |
|
|
|
|
|
|
|
|
|
|
22 |
20 |
37 |
33 |
125 |
108 |
1~3-H |
|
|
|
|
|
|
|
|
|
|
34 |
32 |
63 |
50 |
176 |
165 |
1~3-M |
|
|
|
|
|
|
|
|
|
|
46 |
43 |
77 |
73 |
233 |
217 |
1~4-m |
|
|
|
|
|
|
|
|
|
|
|
|
27 |
24 |
88 |
72 |
1~4-H |
|
|
|
|
|
|
|
|
|
|
|
|
43 |
40 |
140 |
132 |
1~4-M |
|
|
|
|
|
|
|
|
|
|
|
|
58 |
55 |
180 |
167 |
m= calibration at min span H= calibration at Half span M= calibration at Max span |
* Close by flow rise (L/min) of contact open at no flow position ** Open by flow decrease (L/min) of contact open at no flow position. Average values for indication only. Standard tolerances ±15% |
Main references (With type A cleavable paddle)
Calibration
(Calibration force ±15%, measured at
end of paddle N°1) |
Waterproof connection box with M16x1.5 cable gland |
Waterproof connection box with 4 pins,
M12x1 IEC947-5-2 connector |
Waterproof connection box with DIN
43650-A connector |
Low span end: 3gr |
R1V636680G35N00C |
R1V636680G35N00L |
R1V636680G35N00D |
Middle span:7gr |
R1V676680G35N00C |
R1V676680G35N00L |
R1V676680G35N00D |
High span end:14 gr |
R1V6E6680G35N00C |
R1V6E6680G35N00L |
R1V6E6680G35N00D |
Other paddles (Non cleavable models)
 |
 |
 |
 |
Paddle type B
Replace 6680 in reference by 1234 |
Paddle type C
Replace 6680 in reference by 1549 |
Paddle type D
Replace 6680 in reference by 1564 |
Paddle type E
Replace 6680 in reference by 1579 |
Consult us for flow detection values with these paddles. OEM paddles can be made on order (MOQ apply) |
|