Technical features
Housing: dimensions 43 × 35.2 × 34.5mm (without terminals and bush thread).
Bulb and capillary: stainless steel, with a 100mm long PVC sleeve on the capillary. PTFE sleeving for ranges of 300°C and above. Other sleeving lengths on request. Minimum capillary bending radius: 5mm. For temperature ranges above 300°C, the capillary has a PTFE sleeve over its full length except 150mm on the bulb side.
Temperature sensing element: oil-filled bulb and capillary.
Caution: temperature ranges above 400°C are filled with sodium-potassium eutectic. In case of breakage of the bulb or capillary, this liquid may self-ignite at room temperature in the presence of water or moisture.
Terminals: 6.35 × 0.8mm quick connect terminals, 90° bent. Straight terminals or 30° or 60° bent terminals are also available on request (MOQ applies). Terminal positions and alignment allow the use of a connector with flat or bent terminals.
Adjustment: factory fixed setting, up to 550°C.
Mounting: M10×1 center bush (M8 on request).
Grounding: 6.35 × 0.8mm quick connect terminal as an option.
Contact: SPDT or SPNC.
Electrical rating:
At 250V~ rated voltage:
- Open on temperature rise contact (C-1): 20(3.3)A 250V~, 50-60Hz
- Close on temperature rise contact (C-2): 3A 250V~, 50-60Hz
At 400V~ rated voltage:
- Open on temperature rise contact (C-1): 16(2.6)A 400V~, 50-60Hz
- Close on temperature rise contact (C-2): 2A 400V~, 50-60Hz
Electrical life: 6,000 cycles.
Maximum ambient temperature on body: CE: T125; UL: T105, T125.
Pollution degree: 3 for use at 250V, 2 for use at 400V.
Certificates
- CE-LVD: AN 50734410 0001
- UL: UL-US-26123050-0
- CUL: UL-CA-2690401-0
Main references (M10×1 bush mounting)
Set point up to 300°C (bulb diameter 6mm as standard, 4 or 5mm as an option)
- NC contact: 8AC1------615004 (capillary 1500mm), 8AC1------609004 (900mm), 8AC1------602504 (250mm)
- SPDT contact: 8AT1------615004 (capillary 1500mm), 8AT1------609004 (900mm), 8AT1------602504 (250mm)
Set point from 300 to 550°C (bulb diameter 4mm as standard, 3mm as an option)
- NC contact: 8AC1------C15034 (capillary 1500mm), 8AC1------C09034 (900mm), 8AC1------C02534 (250mm)
- SPDT contact: 8AT1------C15034 (capillary 1500mm), 8AT1------C09034 (900mm), 8AT1------C02534 (250mm)
For M8 bush mounting, replace 8AC1 by 8AC8 or 8AT1 by 8AT8 in the reference.
The ------ stands for the calibration temperature followed by the maximum overheat allowed on the bulb (°C).
Capillary fittings options (shipped assembled on the capillary)
- Nickel plated brass, NBR gasket, for use on liquids up to 130°C: 66RL41LS30000000
- Nickel plated brass, FKM gasket, for use on liquids up to 230°C: 66RL41LS20000000
- Stainless steel 304, NBR gasket, for use on liquids up to 130°C: 66RIMEPM9X1041C7
- Stainless steel 304, FKM gasket, for use on liquids up to 230°C: 66RIMEPM9X1041C8
- Stainless steel 304, graphite gasket, for use on liquids up to 500°C: 66RIMEVM9X1041C9
Accessories
3 way connector, available unassembled with non-crimped female terminals, or assembled with crimped wires (length, gauge and style upon customer request): 66KG3635*. The full 16 character reference is issued upon customer wire type and length specifications.
Many other accessories are available: pockets, flanges, fittings. See the full list in catalogue #1.